900

67

0.51

655

50

12

18

24

1050

75

0.62

865

75

6

9

12

1200

90

0.85

1130

75

8

12

16

1350*

95

1.04

1430

75

8

12

16

1500

100

1.22

1765

75

9

14

17

1800

115

1.70

2545

75

11

16

21

2100

125

2.06

3465

75

12

18

24

2400

140

2.69

4525

75

14

21

28

2700

152

3.20

5910

75

16

24

32

3000

175

4.08

7070

75

18

27

36

* DN1350 can be supplied but not Kitemarked.

1000 litres = 220 gallons = 1 cubic metre

PERFORATIONS

The British Standard requires a minimum area of perforations of 50,000mm2 of perforations per metre depth per metre of nominal diameter. Hughes products meet this requirement.

soakaway

Where required Soakaway units are designed to be used with Standard Manhole Sections and Cover Slabs.

STEPS

Can be supplied with or without double steps as required, except DN900 (only supplied without steps).
 

hughesnumbers1
prismlink1
copyright1

titlecompany
HUGHES CONCRETE LIMITED

 

Manufactured and Kitemarked to BS EN 1917:2002 and BS 5991-3:2002

SOAKAWAYS